1. General teatures & merit
- Approximate cycle time : 8 Batteries / Min. based on LN3 Battery
- 1 battery per cycle
- Testing voltage : AC 1.0kV-15kV adjustable
- The adjustable range of detecting current is 0.50mA - 0.05mA and it is accurate to 0.01mA.
- It can be detected Heat seal area of cover to case and Pin hole for bottom of case.
- Reject station included
- But it’s difficult to check heat seal area of cover to cover on top side.
2. Machine details
- Applicable battery size : L185 - 410, W125 - 180, H170 - 250 (in mm)
- Adjustment of the high voltage value
· Test voltage : up to 25kV
- Reject station included
- Frame & Cover material : SUS316L, SS41, PVC, PP
- Air part : SMC
- Main power : 3kW
- Control PLC : MITSUBISHI (USER OPTION)
- Approx. size & weight : L2,000 × W1,500 × H2,300mm / 800kg
3. Utility
Standard electrical power | 220 / 380 / 440V * 3-phase * 50 / 60Hz (USER OPTION) |
---|---|
Compressed air | 5 ~ 6kg / ㎠ |