1. General teatures & merit
- Cycle Time : Approx. 4.5 Batteries / Min. of LN3 Battery
- 1st station : Leak tester (2 heads)
Using Fukuda DG 960 testing unit (Accuracy : 0.00015kg / cm2)
1st, 3rd and 5th cell check first, then 2nd, 4th and 6th cell check
- 2nd station : Reject station
- 3rd station : MFG. code marking unit
2. Machine details
- Applicable battery size : L185 - 410, W125 - 180, H170 - 250 (in mm)
- Air part : SMC
- Main power : 2kW
- Control PLC : MITSUBISHI (USER OPTION)
- Approx. size & weight : L3,500 × W946 × H2,000mm / 1,600kg
3. Utility
Standard electrical power | 220 / 380 / 440V * 3-phase * 50 / 60Hz (USER OPTION) |
---|---|
Compressed air | 5 ~ 6kg / ㎠ |